In vitro cytotoxic effects of DEHP-alternative plasticizers and their primary metabolites on a L929 cell line

2017

IF 4.208; International audience; Phthalic acid esters have been widely used to improve the plasticity of PVC medical devices. They carry a high exposure risk for both humans and the environment in clinical situations. Our study focuses on the cytotoxicity of alternative plasticizers. Postulated primary metabolites were synthesized, not being commercially available. Cytotoxicity assays were performed on L929 murine cells according to the ISO-EN 10993-5 standard design for the biocompatibility of medical devices. The tested concentrations of plasticizers (0.01, 0.05 and 0.1 mg/ml) covered the range likely to be found in biological fluids coming into direct contact with the medical devices. D…

0301 basic medicineEnvironmental EngineeringMetabolite synthesisBiocompatibilityCell SurvivalCytotoxicityHealth Toxicology and MutagenesisMetabolitePhthalic AcidsIn Vitro TechniquesDEHP-alternative plasticizers010501 environmental sciences01 natural sciences[ SDE ] Environmental SciencesMice03 medical and health scienceschemistry.chemical_compoundPhthalatesPlasticizersIn vivoDiethylhexyl PhthalateAnimalsEnvironmental ChemistryOrganic chemistryPolyvinyl ChlorideCytotoxicityCells Cultured0105 earth and related environmental sciences[SDV.MHEP.RSOA] Life Sciences [q-bio]/Human health and pathology/Rhumatology and musculoskeletal systemChromatography[SDV.MHEP.GEG] Life Sciences [q-bio]/Human health and pathology/Geriatry and gerontology[SDV.MHEP.GEG]Life Sciences [q-bio]/Human health and pathology/Geriatry and gerontologyPublic Health Environmental and Occupational HealthPlasticizerPrimary metaboliteEstersGeneral MedicineGeneral ChemistryFibroblastsPollutionIn vitro3. Good healthPhthalic acid030104 developmental biology[SDV.MHEP.RSOA]Life Sciences [q-bio]/Human health and pathology/Rhumatology and musculoskeletal systemchemistryChemosphere
researchProduct

Testing physiologic monitor alarm customization software to reduce alarm rates and improve nurses’ experience of alarms in a medical intensive care u…

2018

BACKGROUND:Clinicians in intensive care units experience alarm fatigue related to frequent false and non-actionable alarms produced by physiologic monitors. To reduce non-actionable alarms, alarm settings may need to be customized for individual patients; however, nurses may not customize alarms because of competing demands and alarm fatigue. OBJECTIVE:To examine the effectiveness and acceptance of physiologic monitor software to support customization of alarms. METHODS:This pre/post intervention study was conducted in a 56-bed medical intensive care unit. IntelliVue® Alarm Advisor customization support software for alarm limit violations was installed on all monitors and education on its u…

MaleTime FactorsPolymersHealth Care ProvidersRespiratory Tract Diseaseslcsh:MedicineNursesBlood PressureSurveysPathology and Laboratory Medicine01 natural sciencesVascular MedicinePersonalization0302 clinical medicineSoftwareHeart RateSoftware DesignMedicine and Health SciencesMedicine030212 general & internal medicineMedical Personnellcsh:SciencePolyvinyl ChlorideMaterialsFatigueMultidisciplinarySoftware EngineeringMiddle AgedHospitalsProfessionsIntensive Care UnitsChemistryMacromoleculesResearch DesignClinical AlarmsPhysical SciencesEngineering and TechnologyEquipment FailureFemaleMedical emergencyResearch ArticleComputer and Information SciencesMaterials ScienceCardiologyResearch and Analysis MethodsCommunicable DiseasesSoftware implementation03 medical and health sciencesALARMSigns and SymptomsRespiratory RateDiagnostic MedicineIntensive careHumansIn patientArterial PressureGlasgow Coma Scale0101 mathematicsAgedMonitoring PhysiologicSurvey Researchbusiness.industrylcsh:R010102 general mathematicsGlasgow Coma Scalemedicine.diseasePolymer ChemistryHealth CareMedical intensive care unitHealth Care FacilitiesPeople and Placeslcsh:QPopulation GroupingsbusinessSoftwarePLoS ONE
researchProduct

Assessment of the cortical bone thickness using ultrasonic guided waves: Modelling and in vitro study

2007

Determination of cortical bone thickness is warranted, e.g., for assessing the level of endosteal resorption in osteoporosis or other bone pathologies. We have shown previously that the velocity of the fundamental antisymmetric (or flexural) guided wave, measured for bone phantoms and bones in vitro, correlates with the cortical thickness significantly better than those by other axial ultrasound methods. In addition, we have introduced an inversion scheme based on guided wave theory, group velocity filtering and 2-D fast Fourier transform, for determination of cortical thickness from the measured velocity of guided waves. In this study, the method was validated for tubular structures by usi…

Materials scienceAcoustics and UltrasonicsBiophysicsModels BiologicalRadius boneOpticsBone DensitymedicineHumansUltrasonicsRadiology Nuclear Medicine and imagingQuantitative computed tomographyPolyvinyl ChlorideUltrasonographyGuided wave testingRadiological and Ultrasound Technologymedicine.diagnostic_testPhantoms Imagingbusiness.industryUltrasoundReproducibility of ResultsRadiusmedicine.anatomical_structurePlate theoryCortical boneUltrasonic sensorTomographyTomography X-Ray ComputedbusinessBiomedical engineeringUltrasound in Medicine & Biology
researchProduct

Thickness sensitivity of ultrasound velocity in long bone phantoms

2004

One approach to bone disease diagnosis such as osteoporosis is to measure the velocity of ultrasound propagating axially along long bones. In this study, the variation in velocity as a function of radial position was assessed using two polyvinyl chloride (PVC) bone phantoms with cross-sectional geometry similar to the human tibia but differing in medullary cavity diameter. Two ultrasonometers were used: these were a commercial device operating at a relatively high frequency (HF) of 1.25 MHz and a prototype low frequency (LF) device operating at approximately 200 kHz. The LF measurements showed a larger variation with radial position, with changes in velocity of up to 20% occurring around th…

Materials scienceAcoustics and UltrasonicsBone diseaseMedullary cavityLong boneBiophysicsLow frequencyBone and BonesImaging phantommedicineHumansUltrasonicsRadiology Nuclear Medicine and imagingTibiaPolyvinyl ChlorideUltrasonographyTibiaRadiological and Ultrasound TechnologyPhantoms Imagingbusiness.industryUltrasoundAnatomymedicine.diseasemedicine.anatomical_structureOsteoporosisbusinessAxial symmetryBiomedical engineeringUltrasound in Medicine & Biology
researchProduct

Elastic wave propagation in bone in vivo: methodology.

1995

The purpose of this study was to investigate the usefulness of elastic wave propagation (EWP) in estimating the mechanical properties (elasticity) of human tibia. The test group was composed of 78-yr-old women assigned to high (n = 19) and low (n = 17) bone mineral density (BMD) groups as measured at the calcaneus by the 125I-photon absorption method. The EWP apparatus consisted of an impact-producing hammer with a force strain gauge and two accelerometers positioned on the bone. Results for nylon and acrylic were used to calibrate the apparatus. Polyvinyl chloride (PVC) solid rods and tubes of various diameters were used to evaluate the relationship between the elastic wave velocity and cr…

Materials scienceBone densityAccelerationTransducersBiomedical EngineeringBiophysicsAcrylic ResinsSecond moment of areaMineralogylaw.inventionFractures BonelawBone DensityAnimalsHumansOrthopedics and Sports MedicineHammerComposite materialElasticity (economics)Polyvinyl ChlorideStrain gaugeAgedBone mineralTibiaRehabilitationElasticityNylonsCalibrationCattleFemaleTomographyCalcaneusStress MechanicalTomography X-Ray ComputedAlgorithmsJournal of biomechanics
researchProduct

Ion-Selective Organic Electrochemical Transistors

2014

Ion-selective organic electrochemical transistors with sensitivity to potassium approaching 50 μA dec(-1) are demonstrated. The remarkable sensitivity arises from the use of high transconductance devices, where the conducting polymer is in direct contact with a reference gel electrolyte and integrated with an ion-selective membrane.

Materials scienceConductometryTransistors ElectronicTransconductanceInorganic chemistryBiosensing TechniquesElectrolyteElectrochemistrylaw.inventionlawGeneral Materials ScienceOrganic ChemicalsPolyvinyl ChlorideIonsConductive polymerbusiness.industryMechanical EngineeringTransistorMembranes ArtificialEquipment DesignEquipment Failure AnalysisMembraneMechanics of MaterialsPotassiumOptoelectronicsbusinessBiosensorOrganic electrochemical transistorAdvanced Materials
researchProduct

Influence of small amounts of polyvinylchloride on the recycling of polyethyleneterephthalate

1999

Abstract Polyethylene terephthalate (PET), and polyvinyl chloride (PVC), are commonly encountered in plastics stream coming from separate collections of plastic bottles. The presence of PVC in the recycled PET is very dangerous because of the chain scission provoked by the hydrogen chloride evolved from the macromolecules during degradation of PVC. Recycled PET must be free of PVC; contents of PVC as little as 100 ppm can induce degradation and discoloration of the polyester. PET, in its turn, is degraded when the processing is carried out in the presence of water. In previous work, however, the degradation of PET was eliminated and rather an increase of the molecular weight has been measur…

Materials sciencePolymers and PlasticsChain scissionNitrogen atmosphereCondensed Matter PhysicsPolyesterPolyvinyl chloridechemistry.chemical_compoundchemistryMechanics of MaterialsMaterials ChemistryPolyethylene terephthalateDegradation (geology)Nitrogen flowComposite materialHydrogen chloridePolymer Degradation and Stability
researchProduct

Preparation and Characterization of Composites Materials with Rubber Matrix and with Polyvinyl Chloride Addition (PVC)

2020

An important problem that arises at present refers to the increase in performances in the exploitation of the conveyor belts. Additionally, it is pursued to use some materials, which can be obtained by recycling rubber and PVC waste, in their structure. Thus, the research aimed at creating conveyor belts using materials obtained from the recycling of rubber and PVC waste. Under these conditions, conveyor belts were made that had in their structure two types of rubber and PVC, which was obtained by adding in certain proportions of reclaimed rubber and powder obtained from grinding rubber waste. In order to study the effect of adding PVC on properties, four types of conveyor belts were made, …

Materials sciencePolymers and Plasticsfinite element methodrubber02 engineering and technologyTensile strain010402 general chemistry01 natural sciencesArticlelcsh:QD241-441chemistry.chemical_compoundlcsh:Organic chemistryNatural rubberaccelerated agingComposite materialTextile reinforcementGeneral Chemistry021001 nanoscience & nanotechnologymaterials structure analysisAccelerated aging0104 chemical sciencesGrindingPolyvinyl chloridechemistryvisual_artvisual_art.visual_art_mediumpolyvinyl chloride0210 nano-technologyPolymers
researchProduct

Resource or waste? A perspective of plastics degradation in soil with a focus on end-of-life options.

2018

‘Capable-of-being-shaped’ synthetic compounds are prevailing today over horn, bone, leather, wood, stone, metal, glass, or ceramic in products that were previously left to natural materials. Plastic is, in fact, economical, simple, adaptable, and waterproof. Also, it is durable and resilient to natural degradation (although microbial species capable of degrading plastics do exist). In becoming a waste, plastic accumulation adversely affects ecosystems. The majority of plastic debris pollutes waters, accumulating in oceans. And, the behaviour and the quantity of plastic, which has become waste, are rather well documented in the water, in fact. This review collects existing information on pla…

PLA polylactic acidPS polystyreneETS European Emissions Trading schemePOM polyoxymethyleneHMC heat melt compactor technology02 engineering and technology010501 environmental sciencesNHV net habitable volumeLDPE low-density polyethylene01 natural sciencesPC polycarbonateResin identification codeLCP liquid crystal polymerslcsh:Social sciences (General)PAC pro-oxidant additive containingPET polyethylene terephthalateEPR Extended Producers ResponsibilityMultidisciplinaryWaste managementNatural materials021001 nanoscience & nanotechnologyPU or PUR polyurethaneSettore AGR/02 - Agronomia E Coltivazioni ErbaceeEPS expandable polystyreneRIC resin identification codeSettore AGR/14 - PedologiaPVDF polydifluoroethylenelcsh:H1-990210 nano-technologyBiogeoscienceGPPS Polystyrene (General Purpose)PVC polyvinyl chlorideResource (biology)Polymethyl methacrylatePA polyamidePBT polybutylene terephthalatePSU polyarylsulfonePTFE polytetrafluoroethylenePMMA polymethyl methacrylatePHA polyhydroxyalkanoateMicrobiologyPEEK polyaryletheretherketoneArticleEnvironmental scienceEnvironmental science Biogeoscience Industry MicrobiologyPPA polyphthalamideTPE thermoplastic polyester elastomerNatural degradationIndustryPPS polyphenylene sulphidelcsh:Science (General)ABS acrylonitrile-butadiene-styrene0105 earth and related environmental sciencesbusiness.industryPP polypropyleneHDPE high-density polyethyleneBPA bisphenol AHBCD hexabromocyclododecaneFuture studyAgricultureDOM dissolved organic matterDegradation (geology)Environmental sciencebusinesslcsh:Q1-390Heliyon
researchProduct

Modification of EVOH copolymers with e-caprolactone: synthesis and compatibilization effects in PE/PVC blends

2001

Polyethylene-polycaprolactone graft copolymers with different chemical structures (i.e. different number and length of PCL grafts and molecular weight of PE backbone) were synthesized from various EVOH copolymers and e-caprolactone, using Aluminum isopropoxide as catalyst, and were tested for their compatibilizing capability in PE/PVC blends. PE and PCL segments in the graft copolymers were found completely immiscible, while PCL segments of the graft copolymers were found completely miscible with PVC. When graft copolymers were added to PE/PVC blends they proved to be good agents for the dispersion of PVC phase in the PE matrix. SEM showed also improved adhesion between the dispersed PVC ph…

POLYETHYLENEMaterials sciencePolymers and PlasticscompatibilizationOrganic ChemistryINCOMPATIBLE POLYMERSConcentration effectCompatibilizationPolyethyleneCondensed Matter PhysicsGraftingchemistry.chemical_compoundPolyvinyl chloridecompatibilization; polymer blends; ethylene-co-vinyl alcoholBLOCK-COPOLYMERSPOLYMER BLENDSSettore ING-IND/22 - Scienza E Tecnologia Dei Materialichemistryethylene-co-vinyl alcoholMaterials ChemistryCopolymerPolymer blendComposite materialCaprolactonepolymer blends
researchProduct